Eco Light Supply Ballast Compatible OR BYPASS - (UL+DLC) 18W 4000K T8 4ft LED Tube

  • SKU: ELS-18W-BC-4k-T8
Ballast Compatible OR BYPASS - (UL+DLC) 18W 4000K T8 LED Tube 2160 Lumens 4ft Learn More
Low Price Gurantee

$20.99

$14.99

Status: In stock
Learn more
Eco Light Supply Ballast Compatible OR BYPASS - (UL+DLC) 18W 4000K T8 4ft LED Tube

Basic Feature -


T8 direct replacement ballast compatible led tubes are an energy saving product as special replacement for traditional flourescent T8 lamps


- Designed to operate on existing all instant start ballast,rapid start ballast,programmed star ballast and emergency fixture with input voltage of AC120-277V, AC347V.


- Ttubes minimize labor and recycling costs.


- THD less than 20%,


Power factor more than 0.90.


- Reduces energy consumption up to 40%.


- Stable lumens output for different ballast brand with different ballast factor.


- No UV emission.


- This tube only work with ballast.


 


Detailed Data


 


Ballast Compatible Led Tube


- Wattage:15W


- Life Span:50000 Hours


- Weight:360g


- Led Chip:96 pieces of SMT 2835


- Power Factor:More than 0.90


- Efficiency:l20 lm/W


- Certificates:DLC,UL,cUL,NSF,Lighting Facts,RoHs DLC model as below ( (only for G13 pins and non Rotating end caps):


 


Installation Instruction


Prepair for Installation


- Check the ballast installed in the field and make sure the ballast is in manufacturer's ballast list. If the ballast out of the list, a test must needed before mass installation. - Loose and damaged lamp holder and socket need to be adjusted or be replaced. "Plug" and "Play" procedure


- Turn off the power to the light fixture at the breaker panel before installation.


- Open the diffuser from the light fixture.Ensure pins are firmly seated in lampholders.


- Remove the flourescent tubes, Please dispose of these items properly as they contain mercury.


- Put led tube into the lighting fixture.


- Install the Led tube,close the diffuser.


- Turn on the power.


Caution - Use only with ballast.


- Risk of fire.Do not install this lamp in a pre-heat luminaire.


- Risk of electric shock.


- Use only in place of fluorescent lamps specified on label or as a retrofit kit.


- This lamp is not intended for use with emergency exists.


- These lamps are to be used in indoor damp location only.Do not suitable for wet location


. - These lamps are not to be used with a light dimmer.


- If the lamp or luminaire exhibits undesirable operation (Buzzing, Flickering, etc), immediately turn off power,remove lamp from luminaire and contact manufacturer.


- This lamp only operates on electronic ballasts or without any ballast.If lamp does not light when the luminaire is energized, remove this lamp from luminaire and contact manufacturer


- Do not make mass installation before sample testing.